LEONARDO: UPS 6 – 10 kVA 1/1

Compact UPS

6-10 kVA On-line 1-phase

On-line 1-phase (VFI) for server rooms, TLC equipment, Emergency and safety systems.
 

  • On-Line 1-phase UPS, ideal for medium and large businesses, advanced power protection for servers rooms, TLC equipment, emergency and safety systems
  • On-line UPS double conversion UPS from 6 to 10 kVA
  • Available in Tower and a flexible Rack/Tower 2U design allowing the unit to be configured for rack-mount or free standing applications
  • Parallel redundant configuration maximizing the availability
  • Extendble runtime

 

Benefits:
  • On-Line double conversion technology corrects all power failures for maximum reliability and protection
  • User-friendly, plug and play, ready to use
  • Battery extension box providing longer autonomy
  • Active harmonic power quality control with THD <3%
  • Automatic self test and advanced battery management maximizing battery performance and extending battery life
  • High efficiency and Eco mode reduce overall power losses guaranteeing low running cost and low environmental impact
  • Borri Power Guardian user-friendly UPS management software with alerts upon main power failures and system shutdown notification via SMS and email free downloadable at www.borri.it/support

 

Features:
  • Input Power Factor 0.99 and THD <3%
  • High double conversion efficiency and ECO mode for low running costs and environmental impact
  • Smart cooling system ensuring further energy savings
  • Full compliance with all international product standards
  • UPS and display panel can be rotated allowing tower or rack-mount configurations
  • Internal manual bypass for safe and easy maintenance
  • Remote emergency power off for immediate UPS shutdown
  • Audible alarm alerts upon utility power and UPS status change
  • Two slots auto-sensing for communication cards
  • Audible alarm alerts upon utility power and UPS status change
  • USB and RS232 communication port providing UPS management
  • Hardwired with two input, output and bypass wires for Tower model from 6 to 10 kVA
  • Hardwired with two input and output wires for Rack/Tower model from 6 to 10 kV

LEONARDO 6-10 kVA On-line 1-phase technical data

UPS Type T * T * RT (2U)*** RT (4U)** RT (3U)***
Rating (kVA) 6 10 6 6 10
Nominal power (kW) 5.4 9 5.4 5.4 9
UPS dimensions WxDxH (mm) 290x645x748 290x645x748 440x680x88 440x680x176 440x680x132
UPS weight (kg) 86 96 24 52 26

*Tower with internal battery **Rack/Tower with internal battery ***Rack/Tower without internal battery

Input

Connection type Hardwired 2w (input), 2w (bypass) Hardwired 2w (input)
Nominal voltage 230 Vac single phase
Voltage tolerance 195÷260 Vac
Frequency and range 50/60 Hz, 45÷65 Hz
Power factor 0.99
Current distortion (THDi) <6%

Output

Connection type Hardwired 2w
Nominal voltage 230 Vac +/- 1% single phase
Frequency 50/60 Hz
Power factor Any power factor up to 0.9 lagging or leading without power derating
Overload capability 104% continuous, 105-150% for 160 seconds, >150% immediately transfer to bypass
Mode of operation On-line, Eco mode

Battery

Autonomy time with
internal battery (min)*
50% load 25 17 external battery 15 external battery
100% load 9 6 external battery 6 external battery

* Measurement conditions: optimised parameters, battery full charged, cos Ø 0.7

Connectivity and function extensions

Front panel Display LCD, LED signaling, function keys
Communication Included: RS232 card, USB, EPO
Communication Optional: RS485 card, dry contact card, SNMP card, second RS232 card
Compatible platforms: Microsoft Windows, Linux, Mac

Environmental

Operating temperature 0°C ÷ +40°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 with reduction of 0.5% per 100 m
Audible noise at 1m (dBA) <50
Relative humidity 0-90%

Standards and certifications

Quality assurance, environment,
health and safety
ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
Safety IEC EN 62040-1
EMC IEC EN 62040-2
Marking CE